Thermo Scientific X-ray fluorescence spectrometers

Analytical Instrumentation

Fluid Catalytic Cracking (FCC) catalyst analysis using Thermo Scientific X-ray fluorescence spectrometers
The petrochemical industry relies heavily on FCC catalysts for the production of a variety of organic intermediate building blocks. Usually, this type of material is doped with precious metals such as platinum or palladium. The precious metal concentrations are often directly related to catalyst performance. Poisoning of the catalysts by common petroleum contaminants such as copper is a concern when optimizing the conversion process. Hence, monitoring the composition of FCC catalysts allows higher conversion yields in petrochemical refineries.
XRF offers particular advantages when analyzing FCC catalysts. It is the only technique capable of analyzing solids without laborious sample preparation. Other techniques often require a lengthy chemical digestion before actual analysis. XRF also offers multi-element analysis capability combined with a wide dynamic ranging from ppm up to % levels. For these reasons XRF is also adopted as preferred technique to analyze FCC catalysts by international bodies such as ASTM (e.g. ASTM D7085). The remainder of this article describes the use of Energy Dispersive XRF and Wavelength Dispersive-XRF for the analysis of catalysts.
Catalyst screening with the Thermo Scientific ARL QUANT’X EDXRF analyzer
The ARL QUANT’X EDXRF analyzer is used to determine platinum (Pt) and chlorine (Cl) content of aluminosilicate catalysts. The 50 Watt QUANT’X is equipped with a 3 mm thick Si(Li) detector. The sensitivity of this detector allows sub ppm detection limits for heavy elements such as platinum and other precious metals. Catalyst powders are measured as received by transferring 4 g of powder into an XRF cup sealed with a 4 µm thick polypropylene film on one side and a mesoporous film on the other side. The mesoporous film allows analysis in vacuum avoiding the use of helium which would add extra cost. Total analysis time equals 100 s. Table 1 shows the repeatability values for this application.

Conclusions
Either by using EDXRF or WDXRF the examples of this article shows that XRF distinguishes itself as a fast tool for a variety of FCC catalyst analyses. While EDXRF is more suitable to screen catalyst composition, WDXRF is the preferred technique when high throughput and repeatability are required.
To see our complete product portfolio, please visit www.thermoscientific.com/xpetro

zoom

Table 1: RSD repeatability values on Pt and Cl in FCC catalysts.
zoom

Figure 1: Calibration curve for sulfur in dicating a standard error of estimate of 0.011% m/m.
zoom

Table 2: RSD repeatability values for the ARL ADVANT’X on copper, mercury and sulfur determination in FCC catalysts.


MEBA – Technical Profile Metals of Bahrain (MEBA)

1. Tool room / Engineering Center
  • 2 x 3D Router Machine
  • Wood Processing Unit
2. Automatic Cold Box Core Making.
3. Self Set Molding.
4. Sand Reclamation
5. Continuous Mixer (Furan Sand)
6. Melting
  • Dual Track 750 Kw Induction Furnace with two Crucibles of 1 tone capacity
  • Dual Track 175 Kw Induction Furnace with two
    Crucibles of 250 kgs capacity
7. Shot Blast Chamber
8. Fettling and Finishing
9. Heat Treatment Furnaces with fork type quenching facility and chart recorder.
  • Two tone batch capacity with 1950x1500x1000 mm
  • 500 Kg. batch capacity with 1200x1200x
    800mm chamber sizechamber size
10. Pneumatic Glass Beads Blast
11. Inspection and Testing
Machine Shop
1. C.N.C. Machining centers
2. Vertical Machine Center (VMC)
3. Turn Mill Center
4. 2 x Wickman Multi Spindle Auto Lathes
5. 2 x Rossini –Threading and Multi-station Transfer Machine
6. Milling
7. Trimming process
8. Gang Drills
9. Turret Lathe
10. Grinding Machines
11. Center Lathe Machine
Quality Control (ISO 9001‐2000 QMS)
• ARL Spectrometer
• Non Destructive Testing (NDT)
• Tensile Testing
• Hardness Testing
• Sand Lab
• Microstructure Examination
• Die penetrant Test
ALLOYS